Graded Exercise Test: VO₂max & Ventilatory Thresholds
Last week you predicted VO₂max from a run. This week you measure it. Volunteers complete a graded treadmill test while a gas analyzer measures every breath, and the class uses the data to find VO₂max, the two ventilatory thresholds, and how closely the ACSM equations predict real oxygen cost.
Overview
A graded exercise test (GXT) with gas analysis is the reference method for cardiorespiratory fitness. Workload rises step by step while the analyzer measures oxygen uptake (VO₂) and ventilation (VE). From that one test you get VO₂max, two ventilatory thresholds (VT1 and VT2) that define training zones, and the oxygen cost of each submaximal speed.
Learning objectives
- Calibrate and fit a metabolic analyzer and run a graded treadmill test safely.
- Apply VO₂max criteria (plateau, HR, RPE, and RER when CO₂ is measured).
- Identify VT1 and VT2 from ventilatory data and convert them to heart-rate training zones.
- Compare measured submaximal VO₂ with the ACSM walking and running equations.
- Compare measured VO₂max with the Week 6 field-test predictions for the same people.
| Your equipment | What you can measure this week |
|---|---|
| VO₂-only analyzer (e.g., VO2 Master) + HR strap | VO₂, VO₂max and plateau, VE, breathing rate and tidal volume, VT1 and VT2 from ventilation, HR zones, economy |
| Full metabolic cart (O₂ + CO₂) | All of the above, plus VCO₂, RER (fuel use and the RER ≥ 1.10 criterion), and thresholds from the ventilatory equivalents for both gases |
| No analyzer | Run the same protocol with HR and RPE, and analyze the backup data set (two participants, cart-style columns) |
| Component | What you do | Time |
|---|---|---|
| Pre-lab reading | Background, interactive tool and one research article | ≈ 25 min |
| Pre-lab quiz (5 pts) | 8-question checkpoint (2 pts) and 3 discussion questions (3 pts) | ≈ 20 min |
| Lab activity | Analyzer calibration and fitting, then a graded treadmill test on two volunteers while the class records HR, RPE and stop criteria | 75 min |
| Lab notebook (15 pts) | VO₂max criteria, VT1 and VT2, HR zones, measured vs ACSM VO₂, discussion | ≈ 60 min |
Pre-Lab Reading ≈ 25 min
Every pre-lab has the same three parts: background reading, one article from the research literature, and the pre-lab quiz and discussion questions you submit before lab.
1. What the analyzer measures
Every breath, the analyzer measures how much air you move (flow, giving VE in L/min) and how much oxygen is missing from the air you breathe out. VO₂ is the volume of oxygen you take up per minute. A VO₂-only device measures O₂ and flow; a full cart also measures CO₂, which gives VCO₂ and the respiratory exchange ratio (RER = VCO₂/VO₂). RER tells you the fuel mix (0.70 = fat, 1.00 = carbohydrate) and rises above 1.0 at very hard intensities as bicarbonate buffers acid and extra CO₂ is breathed off.
2. Was it a true VO₂max?
A test shows a true VO₂max when VO₂ stops rising (a plateau, increase < 150 mL/min or < 2.1 mL·kg⁻¹·min⁻¹) even though the workload keeps climbing. Without a plateau, the highest value is called VO₂peak. Secondary criteria: HR within 10 bpm of age-predicted maximum, RPE ≥ 17, RER ≥ 1.10 (cart only), and blood lactate ≥ 8 mmol/L (optional, Week 5 skills).
3. Two ventilatory thresholds
- VT1 (first ventilatory threshold, ≈ 50–65% VO₂max in most students): VE begins to rise faster than VO₂, and VE/VO₂ starts to climb from its lowest point. It is close to the lactate threshold. Below VT1 you can talk comfortably.
- VT2 (respiratory compensation point, ≈ 80–90% VO₂max): a second, steeper rise in VE as breathing works to blow off CO₂ and offset rising acidity. Above VT2 exercise can be held only for minutes.
- VT1 and VT2 split training into three zones: easy (below VT1), moderate/tempo (between), and high-intensity (above VT2). Write each as a heart rate so it can be used without an analyzer.
4. Protocol you will use
| Phase | Treadmill | Duration | Purpose |
|---|---|---|---|
| Rest (standing) | — | 2 min | Baseline VO₂ and HR |
| Stage 1 | 3.0 mph, 1% | 3 min | Walking economy vs ACSM walking equation |
| Stage 2 | 5.0 mph, 1% | 3 min | Running economy |
| Stage 3 | 6.0 mph, 1% | 3 min | Running economy |
| Ramp | +0.5 mph every minute from 6.5 mph, 1% | to exhaustion (≈ 6–10 min) | VT1, VT2, VO₂max |
| Cool-down | 2.5–3.0 mph, 0% | ≥ 3 min | Recovery HR |
Cycle ergometer alternative: 3 min each at 50, 100 and 150 W, then +25 W per minute (+20 W for smaller or less-trained participants) at 70–90 rpm. Use the ACSM leg-cycling equation for the economy comparison.
5. From the literature ≈ 15 min
Montoye, A. H. K., Vondrasek, J. D., & Hancock, J. B., II. (2020). Validity and reliability of the VO2 Master Pro for oxygen consumption and ventilation assessment. International Journal of Exercise Science, 13(4), 1382–1401. pmc.ncbi.nlm.nih.gov/articles/PMC7523887/
Every analyzer, portable or cart, has to be checked against a criterion. This study shows how that is done and how much error to expect. Read it even if your lab uses a full cart.
Read for:
- What the device measures and what it does not.
- What it was compared with, and at what intensities.
- How large the differences were, and how its test–retest reliability compared with the cart.
Before you come to lab
- Volunteers: complete the PAR-Q+ check with your instructor, and arrive having avoided caffeine for 3 hours, food for 2 hours and hard exercise for 24 hours. Wear running shoes and clothes.
- Everyone: know your role (operator, HR and RPE, timer, safety spotter, recorder) and the stop criteria.
- Bring your Week 6 field-test results for comparison.
Pre-Lab Quiz ≈ 20 min
Two parts, both due before lab (5 pts). Checkpoint (2 pts): eight questions on the background and the article; aim for 7 of 8 before you come to lab. Discussion (3 pts): three short written answers you submit to your course site.
Checkpoint
Discussion questions (submit to your course site)
About 75–150 words each unless stated. Each answer is worth 1 point: correct physiology, specific to this lab, and in your own words. Cite the article (author, year) wherever you use it.
1. What is the difference between VO₂max and VO₂peak? Which criteria would you use to decide which one a test produced (a) with a VO₂-only analyzer and (b) with a full cart?
2. Predict the VO₂ (mL·kg⁻¹·min⁻¹) at 3.0 mph and at 5.0 mph (1% grade) using the ACSM walking and running equations. Show your work, and say whether you expect a novice runner's measured value to be higher or lower than predicted.
3. Using Montoye et al. (2020), explain how large a difference between a volunteer's measured and predicted VO₂max would need to be before you are confident it is real rather than measurement error.
Lab Activity 75 min
Organization
One analyzer tests about two volunteers per 75-minute lab (≈ 30 min each including fitting and cool-down). Ideally the volunteers also ran the Week 6 field tests. Every other student has a role, and the whole class receives both data files.
- Analyzer lead: calibration, mask fit, starts and marks the recording
- Treadmill operator: speeds and grades on the clock
- Safety monitor: behind the treadmill, watches form and symptoms
- HR/RPE recorder: HR and RPE in the last 15 s of each stage and minute
- Criteria checker: calls the plateau and the stop
- Observers: watch the live display and note where breathing changes
Equipment
- VO₂-only analyzer (e.g., VO2 Master, with tablet/phone app) or metabolic cart; masks in several sizes; calibration syringe if required
- Chest-strap HR monitor paired to the analyzer
- Treadmill with safety clip; fan; RPE scale (6–20)
- Disinfectant for masks and sensors (follow the manufacturer's cleaning instructions)
- Optional: lactate analyzer for a post-test sample
Timeline
- 0:00–0:10Analyzer warm-up and calibration (flow and gas, per manufacturer); mask sizing and leak check; consent and screening of volunteer 1.
- 0:10–0:40Volunteer 1: 2-min rest, three 3-min stages, ramp to exhaustion, cool-down. Recorders log HR and RPE; observers mark where breathing changes.
- 0:40–1:10Volunteer 2, roles rotate. Volunteer 1 cools down and gives a recovery HR at 3 and 5 min.
- 1:10–1:15Export both data files (CSV) to the course site; disinfect masks and sensors.
Procedure
- Enter the volunteer's age, sex, height and mass in the analyzer software. Fit the mask: no leaks when the volunteer exhales hard against a covered opening.
- Record 2 minutes standing still on the treadmill. Clip the safety key.
- Run the three economy stages, marking each stage change in the software. Record HR and RPE in the last 15 s of every stage.
- Start the ramp at 6.5 mph and add 0.5 mph every minute. Record HR and RPE each minute. Give steady encouragement.
- Stop when the volunteer signals or cannot keep pace, or for any stop criterion (chest pain, dizziness, unsteady gait, abnormal symptoms). Slow to 3 mph for at least 3 minutes; keep the mask on for the first minute of recovery if you want recovery data.
- Save and export the file. Record peak speed and total ramp time.
Lab Notebook ≈ 60 min · due at the start of next lab
Step 1 — Clean and summarize the data ≈ 15 min
- Average VO₂ over 30-s windows to smooth breath-by-breath noise:
=AVERAGE(J2:J4)for 10-s rows. VO₂max (or peak) = the highest 30-s average. - Economy: mean VO₂ (mL·kg⁻¹·min⁻¹) of the last minute of each 3-min stage vs ACSM prediction; % difference
=(measured-predicted)/predicted*100. - Plateau check: change in VO₂ over the final minute (mL/min). With a cart, also peak RER.
Step 2 — Figures ≈ 20 min
- Figure 1: VO₂ (mL·kg⁻¹·min⁻¹) and HR vs time, with stage boundaries marked.
- Figure 2: VE vs VO₂ (or vs time), with your VT1 and VT2 marked. With a cart, add VE/VO₂ and VE/VCO₂ vs time.
- Table 1: measured VO₂max vs the volunteer's Week 6 Cooper and ACSM estimates; HR at VT1 and VT2; three training zones in bpm.
Step 3 — Discussion ≈ 25 min
- Did the test reach a true VO₂max? Justify with the criteria your equipment allows.
- Where were VT1 and VT2 (time, %VO₂max and HR)? Describe the physiology behind each threshold and give the volunteer's three training zones.
- How closely did the ACSM equations predict measured VO₂ at each stage? Give two reasons a person's economy differs from the equation.
- How did measured VO₂max compare with the Week 6 field estimates? Which estimate was closest, and why?
- What can a full metabolic cart tell you that a VO₂-only analyzer cannot, and when would that matter for a client or athlete?
Grading rubric (15 pts)
| Criterion | Pts | Full credit looks like |
|---|---|---|
| Data processing | 4 | 30-s averages, VO₂max, economy vs ACSM, plateau check |
| Figures & table | 4 | VO₂/HR vs time; VE with VT1/VT2 marked; predicted vs measured table with zones |
| Discussion | 6 | All five questions answered with numbers and correct physiology |
| Presentation | 1 | Clear, labelled, units throughout |